LOGIN TO YOUR ACCOUNT

Username
Password
Remember Me
Or use your Academic/Social account:

CREATE AN ACCOUNT

Or use your Academic/Social account:

Congratulations!

You have just completed your registration at OpenAire.

Before you can login to the site, you will need to activate your account. An e-mail will be sent to you with the proper instructions.

Important!

Please note that this site is currently undergoing Beta testing.
Any new content you create is not guaranteed to be present to the final version of the site upon release.

Thank you for your patience,
OpenAire Dev Team.

Close This Message

CREATE AN ACCOUNT

Name:
Username:
Password:
Verify Password:
E-mail:
Verify E-mail:
*All Fields Are Required.
Please Verify You Are Human:
fbtwitterlinkedinvimeoflicker grey 14rssslideshare1
Mphale, Kgakgamatso; Heron, Malcom (2011)
Publisher: Tellus B
Journal: Tellus B
Languages: English
Types: Article
Subjects:
Wildfires are weakly ionized gas. The ionization is mainly due to plant's inorganic ash content species (more especially potassium), that are emitted from thermally decomposing plant structure into the flame during combustion. The amount of ionization in flames with potassium impurities is influenced by both the temperature and the amount potassium impurities in the flame. A numerical experiment was conducted using a local thermal equilibrium-based model to study the influence of inorganic wildfire contents on wildfire electrical conductivity. Simulated very high intensity wildfires (21–90 MWm-1) were used to quantify steady-state electrical conductivity. Its variation with wildfire plume height is important for high voltage power flashover research. In the simulation, vegetation potassium content was varied from 0.50% to 3.0% on dry weight basis, a reflection of its content in natural vegetation. The model predicted a maximum conductivity of 0.053 mhom-1 in 90 MWm-1 crown fire in vegetation with 3.0% potassium content. A 90 MWm-1 crown fire in vegetation with potassium content of 0.5% was predicted to produce a maximum conductivity of 0.022 mhom-1. Electrical conductivities were lower for a shrub fire with an intensity of 21 MWm-1. The model predicted conductivities of 0.0021 and 0.0009 mhom-1 for potassium content of 3.0 and 0.5% in vegetation, respectively.DOI: 10.1111/j.1600-0889.2007.00281.x
  • The results below are discovered through our pilot algorithms. Let us know how we are doing!

    • Alkemade, M. A. 1979. Fundamentals of Analytical Flame Spectroscopy. Hilger, Bristol.
    • Bekker, H. J. J. and Hoch, D. A. 2002. Analysis of factors contributing to unexplained transmission line faults on a high voltage transmission network. IEEE Africon .6th, 655-660.
    • Butler, C. J. and Hayhurst, A. N. 1998. Kinetics of gas-phase ionization of an alkali metal, A, by the electron and proton transfer reactions: A + H3O+ A +.H20 +H; AOH + AOH2+ + H20 in fuel-rich flames at 1800-2250K. J. Chem. Soc. Faraday Trans. 98, 2729-2734.
    • Butler, B. W., Cohen, J., Latham, D. J., Schuette, R. D., Sopko, P. and co-author. 2004. Measurements of radiant emission power and temperature in crown fires. Can. J. For. Res. 34, 1577-1587.
    • Cruz, G., Butler, B. W., Alexander, M. E., Forthofer, J. M. and R. H. Wakimoto 2006. Predicting the ignition of crown fire above a spreading surface fire. Part I: model idealization. Int. J. Wildl. Fire 15, 47-60.
    • de Groot, W. J., Bothwell, P. M., Taylor, S. W., Wotton, B. M., Stocks, B. J. and co-authors. 2004. Jack pine regeneration and crownfire. Can. J. For. Res. 34, 1634-1641.
    • Fonseca, J. R., Tan, A. L., Silva, R. P., Monassi, V., Assuncao, L. A. R. and co-authors. 1990. Effects of agricultural fires on the performance of overhead transmission lines. IEEE Trans. Power Deliv. 5, 687-694.
    • Frost, L. S. 1961. Conductivity of seeded atmospheric pressure plasmas. J. Appl. Phys. 32, 2029-2037.
    • Itikawa, Y. 1973. Effective collision frequency of electrons in gases. Phys. Fluids 16, 831-835.
    • Jensen, A. P., Frandsen, F. J., Dam-Johansen, K. and Sander, B. 2000. Experimental Investigation of the Transformation and Release to Gas Phase of Potassium and Chlorine during Straw Pyrolysis conditions. Energy Fuels 11, 1026-1032
    • Judd, T. S., Attiwill, P. M. and Adams, M. A.1996. Nutrient Concentrations in Eucalyptus: A synthesis in relation to difference between taxa, sites and components. In: Nutrition of Eucalypts (eds. P. M. Attiwill, and M. A. Adams). CSIRO Publishing, Melbourne, 123-153.
    • Krishna, P. K., Sangen, E. and Visser, P. 1985. Wood burning stove. Adv. Heat Transfer 17, 215-223.
    • Latham, D. 1999. Space charge generated by wind tunnel fires. Atmos. Res. 51, 267-278.
    • Porterie, B., Loraud, J. C., Morvan, D. and Larini, M. 1999. A numerical study of buoyant plumes in cross-flow conditions. Int. J. Wildl. Fire 10, 137-143.
    • Radojevic, M. 2003. Chemistry of forest fires and regional haze with emphasis on Southeast Asia. Pure Appl. Geophys. 12, 157-187.
    • Raison, R. J., Khaina, P. K. and Woods, P. 1985. Mechanisms of element transfer to the atmosphere during vegetation burning. Can. J. Forest Res. 15, 132-140.
    • Sakao, F. and Sato, H. 1969. Nonequilibrium electrical conductivity of potassium - seed argon plasma. Phys. Fluids 12, 2063-2071.
    • Santoni, P. A., Simeoni, A., Rossi, J. L., Bosseur, F., Morandini, F. and co-authors. 2006. Instrumentation of wildland fire: characterization of a fire spreading through a Mediterranean shrub. Fire Safety J. 41, 171-184.
    • Schneider, J. and Hofmann, F. W. 1959. Absorption and dispersion of microwaves in flames. Phys. Rev. 116, 244-249.
    • Shuler, K. E. and Weber, J. 1954. A microwave investigation of the ionisation of hydrogen-oxygen and acetylene-oxygen flames. J. Chem. Phys. 22, 491-502.
    • Sorokin, A., Vancassel, X. and Mirabel, P. 2002. Emission of ions and charged soot particle by aircraft engines. Atmos. Chem. Phys. Discuss. 2, 2045-2074.
    • Sturgeon, R. E., Berman, S. S. and Kashyaps, S. 1980. Microwave attenuation determination of electron concentration in graphite and tantalum tube electrothermal atomizers. Anal. Chem. 52, 1049-1053.
    • Sukhnandan, A. and Hoch, D. A. 2002. Fire Induced flashovers of transmission line: theoretical. IEEE Africon .6th, 617-622.
    • Weber, R. O., Gill, A. M., Lyons, P. R. A. and Mercer, G. N. 1995. Time dependence of temperature above wildland fires. CALM Sci. 4, 17-22.
    • Westberg, H. M., Bystrom, M. and Lecker, B. 2003. Distribution of potassium, chlorine and sulphur between solid and vapour phases during combustion of wood and coal. Energy Fuels 17, 18-28.
    • Williams, R. P., Congdon, R. A., Grice, A. C. and Clarke, P. J. 2003. Effect of fire regime on plant abundance in tropical eucalypt savanna of north-eastern. Aust. Austral Ecol. 28, 327-338.
    • Viegas, D. X. 1998. Forest fire propagation. Phil. Trans. R. Soc. Lond. A356, 2907-2928.
    • Vodacek, A., Kremens, R. L., Fordham, S. C., VanGorden, S. C., Luisi, D. and co-authors. 2002. Remote optical detection of biomass burning using potassium emission signature. Int. J. Remote Sens. 23, 2721- 2726.
  • No related research data.
  • No similar publications.

Share - Bookmark

Cite this article

Collected from