LOGIN TO YOUR ACCOUNT

Username
Password
Remember Me
Or use your Academic/Social account:

CREATE AN ACCOUNT

Or use your Academic/Social account:

Congratulations!

You have just completed your registration at OpenAire.

Before you can login to the site, you will need to activate your account. An e-mail will be sent to you with the proper instructions.

Important!

Please note that this site is currently undergoing Beta testing.
Any new content you create is not guaranteed to be present to the final version of the site upon release.

Thank you for your patience,
OpenAire Dev Team.

Close This Message

CREATE AN ACCOUNT

Name:
Username:
Password:
Verify Password:
E-mail:
Verify E-mail:
*All Fields Are Required.
Please Verify You Are Human:
fbtwitterlinkedinvimeoflicker grey 14rssslideshare1
Price, Owen F.; Horsey, Bronwyn; Jiang, Ningbo (2016)
Publisher: Copernicus Publications
Languages: English
Types: Article
Subjects: G, GE1-350, Geography. Anthropology. Recreation, QE1-996.5, Environmental technology. Sanitary engineering, Environmental sciences, Geology, TD1-1066
Smoke from wildfires poses a significant threat to affected communities. Prescribed burning is conducted to reduce the extent and potential damage of wildfires, but produces its own smoke threat. Planners of prescribed fires model the likely dispersion of smoke to help manage the impacts on local communities. Significant uncertainty remains about the actual smoke impact from prescribed fires, especially near the fire, and the accuracy of smoke dispersal models.

To address this uncertainty, a detailed study of smoke dispersal was conducted for one small (52 ha) and one large (700 ha) prescribed fire near Appin in New South Wales, Australia, through the use of stationary and handheld pollution monitors, visual observations and rain radar data, and by comparing observations to predictions from an atmospheric dispersion model. The 52 ha fire produced a smoke plume about 800 m high and 9 km long. Particle concentrations (PM2.5) reached very high peak values (> 400 µg m−3) and high 24 h average values (> 100 µg m−3) at several locations next to or within ∼ 500 m downwind from the fire, but low levels elsewhere. The 700 ha fire produced a much larger plume, peaking at ∼ 2000 m altitude and affecting downwind areas up to 14 km away. Both peak and 24 h average PM2.5 values near the fire were lower than for the 52 ha fire, but this may be because the monitoring locations were further away from the fire. Some lofted smoke spread north against the ground-level wind direction. Smoke from this fire collapsed to the ground during the night at different times in different locations. Although it is hard to attribute particle concentrations definitively to smoke, it seems that the collapsed plume affected a huge area including the towns of Wollongong, Bargo, Oakdale, Camden and Campbelltown (∼ 1200 km2). PM2.5 concentrations up to 169 µg m−3 were recorded on the morning following the fire. The atmospheric dispersion model accurately predicted the general behaviour of both plumes in the early phases of the fires, but was poor at predicting fine-scale variation in particulate concentrations (e.g. places 500 m from the fire). The correlation between predicted and observed varied between 0 and 0.87 depending on location. The model also completely failed to predict the night-time collapse of the plume from the 700 ha fire.

This study provides a preliminary insight into the potential for large impacts from prescribed fire smoke to NSW communities and the need for increased accuracy in smoke dispersion modelling. More research is needed to better understand when and why such impacts might occur and provide better predictions of pollution risk.
  • The results below are discovered through our pilot algorithms. Let us know how we are doing!

    • Adetona, O., Simpson, C. D., Onstad, G., and Naeher, L. P.: Exposure of Wildland Firefighters to Carbon Monoxide, Fine Particles, and Levoglucosan, Ann. Occup. Hyg., 57, 979-991, 2013.
    • Boer, M. M., Sadler, R. J., Wittkuhn, R., McCaw, L., and Grierson, P. F.: Long-term impacts of prescribed burning on regional extent and incidence of wildfires - evidence from fifty years of active fire management in SW Australian forests, Forest Ecol. Manag., 259, 132-142, 2009.
    • Bradstock, R. A., Cary, G. J., Davies, I., Lindenmayer, D. B., Price, O., and Williams, R. J.: Wildfires, fuel treatment and risk mitigation in Australian eucalypt forests: insights from landscape-scale simulation, J. Environ. Manage., 105, 66-75, 2012.
    • Cruz, M. G., Sullivan, A. L., Gould, J. S., Sims, N. C., Bannister, A. J., Hollis, J. J., and Hurley, R. J.: Anatomy of a catastrophic wildfire: The Black Saturday Kilmore East fire in Victoria, Australia, Forest Ecol. Manag., 284, 269-285, 2012.
    • Engelbrecht, F. A., McGregor, J. L., and Engelbrecht, C. J.: Dynamics of the Conformal-Cubic Atmospheric Model projected climate-change signal over southern Africa, Int. J. Climatol., 29, 1013-1033, 2009.
    • Fromm, M. D., McCRae, R. H. D., Sharples, J. J., and Kablick III, G. P.: Pyrocumulonimbus pair in Wollemi and Blue Mountains National Parks, 22 November 2006, Australian Meteorological and Oceanographic Journal, 62, 117-126, 2012.
    • Haikerwal, A., Reisen, F., Sim, M. R., Abramson, M. J., Meyer, C. P., Johnston, F. H., and Dennekamp, M.: Impact of smoke from prescribed burning: Is it a public health concern?, JAPCA J. Air Waste Ma., 65, 592-598, 2015.
    • Hanigan, I. C., Johnston, F. H., and Morgan, G. G.: Vegetation fire smoke, indigenous status and cardio-respiratory hospital admissions in Darwin, Australia, 1996-2005: a time-series study, Environ. Health-UK, 7, 42, doi:10.1186/1476-069X-7-42, 2008.
    • Hurley, P. J., Physick, W. L., and Luhar, A. K.: TAPM: a practical approach to prognostic meteorological and air pollution modelling, Environ. Modell. Softw., 20, 737-752, 2005.
    • Innis, J.: BLANkET1 Technical Report 22, Burn Brighter 2012, and smoke surveys in Tasmania 2010-2012, Air Section, Tasmanian Environment Protection Agency, Hobart, 2013.
    • Jayachandran, S.: Air Quality and Early-Life Mortality Evidence from Indonesia's Wildfires, J. Hum. Resour., 44, 916-954, 2009.
    • Johnston, F., Hanigan, I., Henderson, S., Morgan, G., and Bowman, D.: Extreme air pollution events from bushfires and dust storms and their association with mortality in Sydney, Australia 1994- 2007, Environ. Res., 111, 811-816, 2011.
    • Jones, T. A. and Christopher, S. A.: Satellite and Radar Remote Sensing of Southern Plains Grass Fires: A Case Study, J. Appl. Meteorol. Clim., 49, 2133-2146, 2010.
    • Keith, D. A.: Ocean shores to desert dunes: The native vegetation of New South Wales and the ACT, Department of Environment and Conservation, Hurstville, NSW, 2004.
    • Lavdas, L. G.: Program VSMOKE User's Manual, USFS Southern Research Station, Asheville, NC, 147 pp., 1996.
    • McGregor, J. L.: Recent developments in variable-resolution global climate modelling, Climatic Change, 129, 369-380, 2015.
    • McNamara, M. L., Noonan, C. W., and Ward, T. J.: Correction factor for continuous monitoring of wood smoke fine particulate matter, Aerosol Air Qual. Res., 11, 315-322, 2011.
    • Meyer, C. P., Lee, S., and Cope, M.: Smoke impacts from prescribed burning in Victoria, developing a risk climatology, 20th International Congress on Modelling and Simulation, Adelaide, Australia, 1-6 December 2013, 200-206, 2013.
    • Mills, G. and McCaw, L.: Atmospheric Stability Environments and Fire Weather in Australia - extending the Haines Index, Centre for Australian Weather and Climate Research, Melbourne, 151 pp., 2010.
    • Miranda, A. I., Martins, V., Cascao, P., Amorim, J. H., Valente, J., Tavares, R., Borrego, C., Tchepel, O., Ferreira, A. J., Cordeiro, C. R., Viegas, D. X., Ribeiro, L. M., and Pita, L. P.: Monitoring of firefighters exposure to smoke during fire experiments in Portugal, Environ. Int., 36, 736-745, 2010.
    • National Pollutant Inventory: Emissions estimation technique manual for aggregated emissions from prescribed burning and wildfires, Environment Australia, Canberra, 1999.
    • Pearce, J. L., Rathbun, S., Achtemeier, G., and Naeher, L. P.: Effect of distance, meteorology, and burn attributes on ground-level particulate matter emissions from prescribed fires, Atmos. Environ., 56, 203-211, 2012.
    • Price, O. F. and Bradstock, R. A.: Quantifying the influence of fuel age and weather on the annual extent of unplanned fires in the Sydney region of Australia, Int. J. Wildland Fire, 20, 142-151, 2011.
    • Price, O. F., Williamson, G. J., Henderson, S. B., Johnston, F., and Bowman, D. J. M. S.: The relationship between landscape fire activity from Modis Hotspots and particulate pollution levels in Australian cities, Plos One, 7, e47327, doi:10.1371/journal.pone.0047327, 2012.
    • Price, O. F., Pausas, J. C., Govender, N., Flannigan, M., Fernandes, P. M., Brooks, M. L., and Bird, R. B.: Global patterns in fire leverage: the response of annual area burnt to previous fire, Int. J. Wildland Fire, 24, 297-306, 2015.
    • Purdham, P. J.: 3D-Rapic - The Australian radar visualisation system, 33rd American Meteorological Society Conference, American Meteorological Society, Cairns, Australia, 2007.
    • Reisen, F. and Brown, S. K.: Impact of prescribed fires on downwind communities, Proceedings of the Royal Society of Queensland, Special Edition: Bushfire 2006 Conference, 115, 85-91, 2009.
    • Reisen, F., Hansen, D., and Meyer, C. P.: Exposure to bushfire smoke during prescribed burns and wildfires: Firefighters' exposure risks and options, Environ. Int., 37, 314-321, 2011.
    • Sapkota, A., Symons, J. M., Kleissl, J., Wang, L., Parlange, M. B., Ondov, J., Breysse, P. N., Diette, G. B., Eggleston, P. A., and Buckley, T. J.: Impact of the 2002 Canadian forest fires on particulate matter air quality in Baltimore City, Environ. Sci. Technol., 39, 24-32, 2005.
    • Tham, R., Erbas, B., Akram, M., Dennekamp, M., and Abramson, M. J.: The impact of smoke on respiratory hospital outcomes during the 2002-2003 bushfire season, Victoria, Australia, Respirology, 14, 69-75, 2009.
    • Trent, A.: Smoke particulate monitors: 2006 update, US Department of Agriculture, Missoula, MT, USA, 15 pp., 2006.
  • No related research data.
  • No similar publications.

Share - Bookmark

Funded by projects

Cite this article