LOGIN TO YOUR ACCOUNT

Username
Password
Remember Me
Or use your Academic/Social account:

CREATE AN ACCOUNT

Or use your Academic/Social account:

Congratulations!

You have just completed your registration at OpenAire.

Before you can login to the site, you will need to activate your account. An e-mail will be sent to you with the proper instructions.

Important!

Please note that this site is currently undergoing Beta testing.
Any new content you create is not guaranteed to be present to the final version of the site upon release.

Thank you for your patience,
OpenAire Dev Team.

Close This Message

CREATE AN ACCOUNT

Name:
Username:
Password:
Verify Password:
E-mail:
Verify E-mail:
*All Fields Are Required.
Please Verify You Are Human:
fbtwitterlinkedinvimeoflicker grey 14rssslideshare1
Pope, Iestyn; Langbein, Wolfgang Werner; Watson, Peter Duncan; Borri, Paola (2013)
Publisher: Optical Society of America
Languages: English
Types: Article
Subjects: QC, RE
We have developed a multimodal multiphoton laser-scanning microscope for cell imaging featuring simultaneous acquisition of differential Coherent Antistokes Raman Scattering (D-CARS), two-photon fluorescence (TPF) and second harmonic generation (SHG) using a single 5 fs Ti:Sa broadband (660-970 nm) laser. The spectral and temporal pulse requirements of these modalities were optimized independently by splitting the laser spectrum into three parts: TPF/SHG excitation (> 900 nm), CARS Pump excitation (< 730 nm), and CARS Stokes excitation (730-900 nm). In particular, by applying an equal linear chirp to pump and Stokes pulses using glass dispersion we achieved a CARS spectral resolution of 10 cm(-1), and acquired CARS images over the 1200-3800 cm(-1) vibrational range selected by the time delay between pump and Stokes. A prism pulse compressor in the TPF/SHG excitation was used to achieve Fourier limited 30 fs pulses at the sample for optimum TPF and SHG. D-CARS was implemented with few passive optical elements and enabled simultaneous excitation and detection of two vibrational frequencies with a separation adjustable from 20 cm(-1) to 150 cm(-1) for selective chemical contrast and background suppression. The excitation/detection set-up using beam-scanning was built around a commercial inverted microscope stand providing conventional bright-field, differential interference contrast and epi-fluorescence for user-friendly characterization of biological samples. Examples of CARS hyperspectral images and simultaneous acquisition of D-CARS, TPF and SHG images in both forward and epi-direction are shown on HeLa cells, stem-cell derived human adipocytes and mouse tissues.

Share - Bookmark

Funded by projects

  • RCUK | Shedding new light on cell...
  • RCUK | Multiphoton microscopy of ...

Cite this article