LOGIN TO YOUR ACCOUNT

Username
Password
Remember Me
Or use your Academic/Social account:

CREATE AN ACCOUNT

Or use your Academic/Social account:

Congratulations!

You have just completed your registration at OpenAire.

Before you can login to the site, you will need to activate your account. An e-mail will be sent to you with the proper instructions.

Important!

Please note that this site is currently undergoing Beta testing.
Any new content you create is not guaranteed to be present to the final version of the site upon release.

Thank you for your patience,
OpenAire Dev Team.

Close This Message

CREATE AN ACCOUNT

Name:
Username:
Password:
Verify Password:
E-mail:
Verify E-mail:
*All Fields Are Required.
Please Verify You Are Human:
fbtwitterlinkedinvimeoflicker grey 14rssslideshare1
Publisher: Blackwell Publishing
Languages: English
Types: Article
Subjects: QL

Classified by OpenAIRE into

mesheuropmc: digestive, oral, and skin physiology
The 13C-octanoic acid breath test has been correlated significantly to radioscintigraphy for measurement of gastric emptying indices in healthy horses. The objective of this study was to investigate the validity of the test for measurement of equine delayed gastric emptying, prior to its potential clinical application for this purpose. A model of atropine- induced gastroparesis was used. Gastric emptying rate was measured twice in 8 horses using concurrent radioscintigraphy and/or breath test after treatment i.v. with either atropine (0.035 mg/kg bwt) or saline in randomised order. Analysis of both data sets demonstrated that the atropine treatment had caused a significant delay in gastric emptying rate. Paired breath test data showed an atropine-induced delay in gastric half-emptying time t(1/2)), with no overlap in the 99% Cl range (P<0.001). Significant correlations were found between scintigraphy and 13C-octanoic acid breath test for calculation of both t(1/2) (P<0.01) and lag phase duration (P<0.05) in the atropine-delayed emptying results. The mean (s.d.) bias in breath test t(1/2) when compared with scintigraphy was 1.78 (0.58) h. The results demonstrated that the 13C-octanoic acid breath test was an effective diagnostic modality for the measurement of equine delayed gastric emptying. The technique offers advantages to existing methods for clinical investigation, as it is noninvasive, not radioactive, quantitative and requires minimal equipment or training to perform.

Share - Bookmark

Download from

Cite this article