Publisher: IOP Publishing
Languages: English
Types: Article
Subjects: RD, QM, TA
Pulse oximeter probes attached to the finger may fail to estimate blood oxygen saturation (SpO2) in patients with compromised peripheral perfusion (e.g. hypothermic cardiopulmonary bypass surgery). The measurement of SpO2 from a central organ such as the oesophagus is suggested as an alternative to overcome this problem. A reflectance oesophageal pulse oximeter probe and a processing system implemented in LabVIEW were developed. The system was evaluated in clinical measurements on 50 cardiothoracic surgery patients. Oesophageal photoplethysmographic (PPG) signals with large amplitudes and high signal-to-noise ratios were measured from various depths within the oesophagus from all the cardiothoracic patients. The oesophageal PPG amplitudes from these patients were in good agreement with previous oesophageal PPG amplitude measurements from healthy anaesthetized patients. The oesophageal pulse oximeter SpO2 results agreed well with the estimated arterial oxygen saturation (SaO2) values inferred from the oxygen tension obtained by blood gas analysis. The mean (+/- SD) of the differences between the oesophageal pulse oximeter SpO2 readings and those from blood gas analysis was 0.02 +/- 0.88%. Also, the oesophageal pulse oximeter was found to be reliable and accurate in five cases of poor peripheral perfusion when a commercial finger pulse oximeter probe failed to estimate oxygen saturation values for at least 10 min. These results suggest that the arterial blood circulation to the oesophagus is less subject to vasoconstriction and decreased PPG amplitudes than are the peripheral sites used for pulse oximetry such as the finger. It is concluded that oesophageal SPO2 monitoring may be of clinical value.
  • The results below are discovered through our pilot algorithms. Let us know how we are doing!

    • Altman D G and Bland J M 1983 Measurement in medicine: the analysis of method comparison studies The Statistician 32 307-17
    • Challoner A V J 1979 Photoelectric plethysmography for estimating cutaneous blood flow Non-invasive Physiological Measurements ed P Rolfe (New York: Academic) ch 6 pp 125-51
    • Clayton D G, Webb R K, Ralston A C, Duthie D and Runciman W B 1991 A comparison of the performance of 20 pulse oximeters under conditions of poor perfusion Anaesthesia 46 3-10
    • Dorlas J C and Nijboer J A 1985 Photo-electric plethysmography as a monitoring device in anaesthesia. Application and interpretation Br. J. Anaesth. 57 524-30
    • Higgins J L and Fronek A 1986 Photoplethysmographic evaluation of the relationship between skin reflectance and blood volume J. Biomed. Eng. 8 130-6
    • Kyriacou P A, Moye A R, Choi D M A, Langford R M and Jones D P 2001 Investigation of the human oesophagus as a new monitoring site for blood oxygen saturation Physiol. Meas. 22 223-32
    • Kyriacou P A, Moye A R, Gregg A, Choi D M A, Langford R M and Jones D P 1999 A system for investigating oesophageal photoplethysmographic signals in anaesthetised patients Med. Biol. Eng. Comput. 37 639-43
    • Lindberg L G and Oberg P A 1991 Photoplethysmography: part 2. Influence of light source wavelength Med. Biol. Eng. Comput. 29 48-54
    • Mendelson Y and Ochs B D 1988 Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography IEEE Trans. Biomed. Eng. 35 798-805
    • Nijboer J A, Dorlas J C and Mahieu H F 1981 Photoelectric plethysmography-some fundamental aspects of the reflection and transmission method Clin. Phys. Physiol. Meas. 2 205-15
    • Reich D L, Imcenko A, Bodian C A, Kraidin J, Hofman J B, Deperio M, Konstadt S N, Kurki T and Eisenkraft J B 1996 Predictors of pulse oximetry data failure Anesthesiology 84 859-64
    • Roberts V C 1982 Photoplethysmography-fundamental aspects of the optical properties of blood in motion Trans. Inst. Meas. Control 4 101-6
    • Rosenberg J and Pedersen M H 1990 Nasal pulse oximetry overestimates oxygen saturation Anaesthesia 45 1070-1
    • Webster J G 1997 Design of Pulse Oximeters (Bristol: Institute of Physics Publishing)