LOGIN TO YOUR ACCOUNT

Username
Password
Remember Me
Or use your Academic/Social account:

CREATE AN ACCOUNT

Or use your Academic/Social account:

Congratulations!

You have just completed your registration at OpenAire.

Before you can login to the site, you will need to activate your account. An e-mail will be sent to you with the proper instructions.

Important!

Please note that this site is currently undergoing Beta testing.
Any new content you create is not guaranteed to be present to the final version of the site upon release.

Thank you for your patience,
OpenAire Dev Team.

Close This Message

CREATE AN ACCOUNT

Name:
Username:
Password:
Verify Password:
E-mail:
Verify E-mail:
*All Fields Are Required.
Please Verify You Are Human:
fbtwitterlinkedinvimeoflicker grey 14rssslideshare1
Lal, S; Hall, RM; Tipper, JL (2016)
Publisher: Elsevier
Languages: English
Types: Article
Subjects:
Ceramics have been used to deliver significant improvements in the wear properties of orthopaedic bearing materials, which has made it challenging to isolate wear debris from simulator lubricants. Ceramics such as silicon nitride, as well as ceramic-like surface coatings on metal substrates have been explored as potential alternatives to conventional implant materials. Current isolation methods were designed for isolating conventional metal, UHMWPE and ceramic wear debris. In this paper, we describe a methodology for isolation and recovery of ceramic or ceramic-like coating particles and metal wear particles from serum lubricants under ultra-low and low wear performance. Enzymatic digestion was used to digest the serum proteins and sodium polytungstate was used as a novel density gradient medium to isolate particles from proteins and other contaminants by ultracentrifugation. This method demonstrated over 80% recovery of particles and did not alter the size or morphology of ceramic and metal particles during the isolation process.
  • The results below are discovered through our pilot algorithms. Let us know how we are doing!

    • [1] [2] [3] Z.M. Jin, J. Fisher, Tribology in joint replacement, in: P.A. Revell (Ed.), Jt. Replace. Technol., 2nd ed., Woodhead Publishing, 2008, pp. 47 - 51.
    • T.R. Green, J. Fisher, M. Stone, B.M. Wroblewski, E. Ingham, Polyethylene particles of a “critical size” are necessary for the induction of cytokines by macrophages in vitro., Biomaterials. 19 (1998) 2297- 302.
    • J.B. Matthews, T.R. Green, M.H. Stone, B.M. Wroblewski, J. Fisher, E. Ingham, Comparison of the response of primary human peripheral blood mononuclear phagocytes from different donors to challenge with model polyethylene particles of known size and dose., Biomaterials. 21 (2000) 2033- [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18] [19] T.R. Green, J. Fisher, J.B. Matthews, M.H. Stone, E. Ingham, Effect of size and dose on bone resorption activity of macrophages by in vitro clinically relevant ultra high molecular weight polyethylene particles., J. Biomed. Mater. Res. 53 (2000) 490-7.
    • R.L. Illgen, T.M. Forsythe, J.W. Pike, M.P. Laurent, C.R. Blanchard, Highly Crosslinked vs Conventional Polyethylene Particles-An In Vitro Comparison of Biologic Activities, J. Arthroplasty. 23 (2008) 721- 731.
    • Bone Joint Surg. Am. 82 (2000) 457-76.
    • A.P.D. Elfick, S.M. Green, S. Krikler, A. Unsworth, The nature and dissemination of UHMWPE wear debris retrieved from periprosthetic tissue of THR., J. Biomed. Mater. Res. A. 65 (2003) 95-108.
    • C.P. Case, V.G. Langkamer, C. James, M.R. Palmer, A.J. Kemp, P.F. Heap, L. Solomon, Widespread dissemination of metal debris from implants., J. Bone Joint Surg. Br. 76 (1994) 701-12.
    • N. Doshi, S. Mitragotri, Macrophages recognize size and shape of their targets., PLoS One. 5 (2010) e10051.
    • H. Yue, W. Wei, Z. Yue, P. Lv, L. Wang, G. Ma, Z. Su, Particle size affects the cellular response in macrophages, Eur. J. Pharm. Sci. 41 (2010) 650-657.
    • F. Billi, P. Benya, A. Kavanaugh, J. Adams, H. McKellop, E. Ebramzadeh, The John Charnley Award: an accurate and extremely sensitive method to separate, display, and characterize wear debris: part 2: metal and ceramic particles., Clin. Orthop. Relat. Res. 470 (2012) 339-50.
    • F. Billi, P. Benya, A. Kavanaugh, J. Adams, E. Ebramzadeh, H. McKellop, The John Charnley Award: an accurate and sensitive method to separate, display, and characterize wear debris: part 1: polyethylene particles., Clin. Orthop. Relat. Res. 470 (2012) 329-38.
    • P. Campbell, S. Ma, B. Yeom, H. McKellop, T.P. Schmalzried, H.C. Amstutz, Isolation of predominantly submicron-sized UHMWPE wear particles from periprosthetic tissues., J. Biomed. Mater. Res. 29 (1995) 127-31.
    • Biomed. Mater. Res. 56 (2001) 245-49.
    • C. Brown, S. Williams, J.L. Tipper, J. Fisher, E. Ingham, Characterisation of wear particles produced by metal on metal and ceramic on metal hip prostheses under standard and microseparation simulation., J. Mater. Sci. Mater. Med. 18 (2007) 819-27.
    • I. Catelas, J.D. Bobyn, J.B. Medley, J.J. Krygier, D.J. Zukor, O.L. Huk, Size, shape, and composition of wear particles from metal-metal hip simulator testing: effects of alloy and number of loading cycles., J. Biomed. Mater. Res. A. 67 (2003) 312-27.
    • I. Catelas, J. Dennis Bobyn, J.J. Medley, D.J. Zukor, A. Petit, O.L. Huk, Effects of digestion protocols on the isolation and characterization of metal-metal wear particles. I. Analysis of particle size and shape, J. Biomed. Mater. Res. 55 (2001) 330-337.
    • B.S. Bal, A. Khandkar, R. Lakshminarayanan, I. Clarke, A. a Hoffman, M.N. Rahaman, Fabrication and testing of silicon nitride bearings in total hip arthroplasty: winner of the 2007 “HAP” PAUL Award., J.
    • Arthroplasty. 24 (2009) 110-6.
    • [22] [23] [24] [25] [26] [27] [28] [29] [30] [31] [32] [33] [34] [35] [36] [37] J. Fisher, X.Q. Hu, J.L. Tipper, T.D. Stewart, S. Williams, M.H. Stone, C. Davies, P. Hatto, J. Bolton, M.
    • Riley, C. Hardaker, G.H. Isaac, G. Berry, E. Ingham, An in vitro study of the reduction in wear of metalon-metal hip prostheses using surface-engineered femoral heads., Proc. Inst. Mech. Eng. H. 216 (2002) 219-30.
    • Res. - Part B Appl. Biomater. 90 (2009) 558-565.
    • Coatings Technol. 200 (2005) 2518-2524.
    • J. Olofsson, T.M. Grehk, T. Berlind, C. Persson, S. Jacobson, Evaluation of silicon nitride as a wear resistant and resorbable alternative for THR, 2 (2012) 94-102.
    • J.D. Chang, Future bearing surfaces in total hip arthroplasty., Clin. Orthop. Surg. 6 (2014) 110-6.
    • E. Laarz, B. V Zhmud, L. Bergstro, Dissolution and Deagglomeration of Silicon Nitride in Aqueous Medium, J. Am. Ceram. Soc. 400 (2000) 2394-2400.
    • M. Al-Hajjar, J. Fisher, J.L. Tipper, S. Williams, L.M. Jennings, Wear of 36-mm BIOLOX(R) delta ceramicon-ceramic bearing in total hip replacements under edge loading conditions., Proc. Inst. Mech. Eng.
    • H. 227 (2013) 535-42.
    • D. Munsterman, S. Kerstholt, Sodium polytungstate , a new non-toxic alternative to bromoform in heavy liquid separation, Rev. Palaeobot. Palynol. 91 (2000) 417-422.
    • A. Seidl, O. Hainzl, M. Richter, R. Fischer, S. Böhm, B. Deutel, M. Hartinger, J. Windisch, N. Casadevall, G.M. London, I. Macdougall, Tungsten-induced denaturation and aggregation of epoetin alfa during primary packaging as a cause of immunogenicity., Pharm. Res. 29 (2012) 1454-67.
    • V. Filipe, A. Hawe, W. Jiskoot, Critical evaluation of Nanoparticle Tracking Analysis (NTA) by NanoSight for the measurement of nanoparticles and protein aggregates., Pharm. Res. 27 (2010) 796-810.
    • M. A. Germain, A. Hatton, S. Williams, J.B. Matthews, M.H. Stone, J. Fisher, E. Ingham, Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro, Biomaterials. 24 (2003) 469-479.
    • ASTM, F1877 - 05 Standard Practice for Characterisation of Particles, 2010.
    • F. Lu, M. Royle, F.V. Lali, A.J. Hart, S. Collins, J. Housden, J.C. Shelton, Simple isolation method for the bulk isolation of wear particles from metal on metal bearing surfaces generated in a hip simulator test, J. Mater. Sci. Mater. Med. 23 (2012) 891-901.
    • K. Wilson, J. Walker, Principles and Techniques of Biochemistry and Molecular Biology, Sixth, Cambridge University Press, 2005.
    • S. Affatato, W. Leardini, M. Zavalloni, Hip Joint Simulators: State of the Art, in: M. Benazzo, Francesco and Falez, Francesco and Dietrich (Ed.), Bioceram. Altern. Bear. Jt. Arthroplast., Steinkopff, 2006: pp.
    • Biomed. Mater. Res. B. Appl. Biomater. 101 (2013) 213-22.
    • A. Wang, G. Schmidig, Ceramic femoral heads prevent runaway wear for highly crosslinked polyethylene acetabular cups by third-body bone cement particles, Wear. 255 (2003) 1057-1063.
    • Eng. H. 214 (2000) 39-47. http://www.ncbi.nlm.nih.gov/pubmed/10718049 (accessed November 5, 2015).
    • [39] J.L. Tipper, P.J. Firkins, A.A. Besong, P.S.M. Barbour, J. Nevelos, M.H. Stone, E. Ingham, J. Fisher, Characterisation of wear debris from UHMWPE on zirconia ceramic, metal-on-metal and alumina ceramic-on-ceramic hip prostheses generated in a physiological anatomical hip joint simulator, Wear.
    • [40] J. Bajorath, W. Hinrichs, W. Saenger, The enzymatic activity of proteinase K is controlled by calcium, Eur. J. Biochem. 176 (1988) 441-447.
    • [41] A.P.D. Elfick, The quantitative assessment of UHMWPE wear debris produced in hip simulator testing: the influence of head material and roughness, motion and loading, Wear. 249 (2001) 517-527.
    • [42] F. Billi, P. Benya, E. Ebramzadeh, P. Campbell, F. Chan, H. A. McKellop, Metal wear particles: What we know, what we do not know, and why, SAS J. 3 (2009) 133-142.
    • [43] E. Zolotarevova, Z. Fejfarkova, G. Entlicher, M. Lapcikova, M. Slouf, D. Pokorny, a. Sosna, Can centrifugation affect the morphology of polyethylene wear debris?, Wear. 265 (2008) 1914-1917.
  • Inferred research data

    The results below are discovered through our pilot algorithms. Let us know how we are doing!

    Title Trust
    56
    56%
  • Discovered through pilot similarity algorithms. Send us your feedback.

Share - Bookmark

Funded by projects

  • EC | LIFELONGJOINTS

Cite this article