LOGIN TO YOUR ACCOUNT

Username
Password
Remember Me
Or use your Academic/Social account:

CREATE AN ACCOUNT

Or use your Academic/Social account:

Congratulations!

You have just completed your registration at OpenAire.

Before you can login to the site, you will need to activate your account. An e-mail will be sent to you with the proper instructions.

Important!

Please note that this site is currently undergoing Beta testing.
Any new content you create is not guaranteed to be present to the final version of the site upon release.

Thank you for your patience,
OpenAire Dev Team.

Close This Message

CREATE AN ACCOUNT

Name:
Username:
Password:
Verify Password:
E-mail:
Verify E-mail:
*All Fields Are Required.
Please Verify You Are Human:
fbtwitterlinkedinvimeoflicker grey 14rssslideshare1
Kyriacou, P. A.; Shafqat, K.; Pal, S. K. (2009)
Publisher: ELSEVIER SCI LTD
Languages: English
Types: Article
Subjects: RC, TK

Classified by OpenAIRE into

mesheuropmc: sense organs
Photoplethysmography (PPG) is a non-invasive electro-optical technique widely used in the monitoring of the pulsations associated with changes in blood volume in a peripheral vascular bed. The technique is based on the absorption properties of vascular tissue when it is transilluminated by light. Photoplethysmography is also used in the estimation of arterial blood oxygen saturation (SpO2) by pulse oximetry where the technique relies on the presence of adequate peripheral arterial pulsations. The aim of this study was to investigate (14 healthy volunteers) the effect of pressure cuff-induced hypoperfusion on PPG signals and SpO2s using a custom made finger blood oxygen saturation PPG/SpO2 sensor and a commercial finger pulse oximeter. PPG signals with high signal-to-noise ratios were obtained from all induced pressures prior to full brachial occlusion. An Analysis of Variance (ANOVA) on ranks showed that there are statistically significant differences (p<0.05) between the PPGs in the low pressures (0–80 mmHg) than those in the upper pressures (90–150 mmHg). Both pulse oximeters showed gradual decrease of saturations during induced hypoperfusion which demonstrate the direct relation between blood volumes (PPG amplitudes), arterial vessel stenosis and blood oxygen saturation. The custom made pulse oximeter was found to be more sensitive to SpO2 changes than the commercial pulse oximeter especially at high occluding pressures.
  • The results below are discovered through our pilot algorithms. Let us know how we are doing!

    • [1] A.V.J. Challoner, Photoelectric Plethysmography for Estimating Cutaneous Blood Flow, Academic Press, New York, 1997.
    • [2] J.C. Dorlas, J.A. Nijboer, Photo-electric plethysmography as a monitoring device in anaesthesia, Application and Interpretation, British Journal of Anaesthesia 57 (1985) 524-530.
    • [3] J.L. Higgins, A. Fronek, Photoplethysmographic evaluation of the relationship between skin reflectance and blood volume, Journal of Biomedical Engineering 8 (1986) 130-136.
    • [4] L.G. Lindberg, P.A. Oberg, Photoplethysmography Part 2: influence of light source wavelength, Medical & Biological Engineering & Computing 29 (1991) 48-54.
    • [5] J.A. Nijboer, J.C. Dorlas, H.F. Mahieu, Photoelectric plethysmographysome fundamental aspects of the reflection and transmission method, Clinical Physics and Physiological Measurement 2 (1981) 205-215.
    • [6] V.C. Roberts, Photoplethysmography - fundamental aspects of the optical properties of blood in motion, Transactions of the Institute of Measurement and Control 4 (1982) 101-106.
    • [7] J. Allen, C.P. Oates, T.A. Lees, A. Murray, Photoplethysmography detection of lower limb peripheral arterial occlusive disease: a comparison of pulse timing, amplitude and shape characteristics, Physiological Measurement 26 (2005) 811-821.
    • [8] J. Allen, Photoplethysmography and its application in clinical physiological measurement, Physiological Measurement 28 (2007) R1-R39.
    • [9] Y. Mendelson, B.D. Ochs, Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography, IEEE Transactions on Biomedical Engineering 35 (1988) 798-805.
    • [10] D.G. Clayton, R.K. Webb, A.C. Ralston, D. Duthie, W.B. Runciman, A comparison of the performance of 20 pulse oximeters under conditions of poor perfusion, Anaesthesia 46 (1991) 3-10.
    • [11] D.L. Reich, A. Imcenko, C.A. Bodian, J. Kraidin, J.B. Hofman, M. Deperio, S.N. Konstadt, T. Kurki, J.B. Eisenkraft, Predictors of pulse oximetry data failure, Anesthesiology 84 (1996) 859-864.
    • [12] K. Irita, Y. Kai, K. Akiyoshi, et al, Performance evaluation of a new pulse oximeter during mild hypothermic cardiopulmonary bypass, Anesthesia and Analgesia 96 (2003) 11-14.
    • [13] P.A. Kyriacou, S. Powell, R.M. Langford, D.P. Jones, Esophageal pulse oximetry utilizing reflectance photoplethysmography, IEEE Transactions of Biomedical Engineering 49 (11) (2002) 1360- 1368.
    • [14] P.A. Kyriacou, Pulse oximetry in the oesophagus, Physiological Measurement 27 (2006) R1-R35.
    • [15] J.T.B. Moyle, Pulse Oximetry, first ed., BMJ Publishing Group, London, 1994.
    • [16] J.G. Webster, Design of Pulse Oximeters, first ed., Institute of Physics Publishing, Bristol, 1997.
  • No related research data.
  • Discovered through pilot similarity algorithms. Send us your feedback.

Share - Bookmark

Cite this article