Pal, S. K.; Kyriacou, P. A.; Kumaran, S.; Fadheel, S.; Emamdee, R.; Langford, R. M.; Jones, D. P. (2005)
Publisher: Elsevier
Languages: English
Types: Article
Subjects: RL, TA
Pulse oximetry is being used in everyday clinical practice in anaesthesia utilising a peripheral probe. However, it may be unreliable in certain clinical situations such as hypothermia, hypovolemia, vasoconstriction and decreased cardiac output. Similar situations occur in burns patients and, more importantly, burns to extremities which limit the sites available for measurement of peripheral oxygen saturation (SpO(2)). To overcome these limitations, the oesophagus has been investigated as an alternative measurement site, as perfusion may be preferentially preserved centrally. A miniaturised reflectance oesophageal saturation (SpO(2)) probe has been constructed utilising infrared and red photodiodes and a photodetector. Our study was aimed at evaluating the reliability of oesophageal pulse oximetry in major burns patients. Seven adult patients (five males, two females) were studied. They were sedated and ventilated as part of their routine care. Measurable photoplethysmographic (PPG) traces and SpO(2) values were obtained in the oesophagus of all patients at a mean depth of 15.6+/-1.8 cm (measured from the lips). It was found that the oesophageal pulse oximeter results were in good agreement with oxygen saturation measurements obtained by a CO-oximeter. The mean (+/-S.D.) of the differences between the oesophageal oxygen saturation results and those from CO-oximetry was 0.50+/-0.69%. A Bland and Altman analysis showed that the bias and the limits of agreement between the oesophageal and commercial toe pulse oximeters were 0.4% and -3.6% to 4.6%, respectively. This study suggests that the oesophagus can be used as an alternative site for monitoring arterial blood oxygen saturation by pulse oximetry in burned patients.
  • The results below are discovered through our pilot algorithms. Let us know how we are doing!

    • [1] Dorlas JC, Kuipers AH. Pulse oximetry-principle and first experiences during anesthesia. Acta Anaesthesiol Belg 1987;38(2):133-8.
    • [2] Freund PR, Overand PT, Cooper J, Jacobson L, Bosse S, Walker B, et al. A prospective study of intraoperative pulse oximetry failure. J Clin Monit 1991;7:253-8.
    • [3] Moller JT, Johannessen NW, Espersen K, Ravlo O, Pedersen BD, Jensen PF, et al. Randomised evaluation of pulse oximetry in 20,802 patients. Anesthesiology 1993;78:436-44.
    • [4] Reich DL, Timcenko A, Bodian CA, Kraidin J, Hofman J, Deperio M, et al. Predictors of pulse oximetry data failure. Anesthesiology 1996;84:859-64.
    • [5] Rosenberg J, Pedersen MH. Nasal pulse oximetry overestimates oxygen saturation. Anaesthesia 1990;45:1070-1.
    • [6] Mendelson Y, Ochs BD. Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography. IEEE Trans Biomed Eng 1988;35:798-805.
    • [7] Kyriacou PA, Moye AR, Gregg A, Choi DMA, Langford RM, Jones DP. A system for investigating oesophageal photoplethysmographic signals in anaesthetized patients. Med Biol Eng Comput 1999;37(5): 639-43.
    • [8] Kyriacou PA, Moye AR, Choi DMA, Langford RM, Jones DP. Investigation of the human oesophagus as a new monitoring site for blood oxygen saturation. Physiol Meas 2001;22(1):223-32.
    • [9] Kyriacou PA, Powell S, Langford RM, Jones DP. Investigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients. Physiol Meas 2002;23(3):533-45.
    • [10] Kyriacou PA, Powell S, Langford RM, Jones DP. Esophageal pulse oximetry utilizing reflectance photoplethysmography. IEEE Trans Biomed Eng 2002;49(11):1360-8.
    • [11] Kyriacou PA, Powell S, Jones DP, Langford RM. Evaluation of oesophageal pulse oximetry in cardiothoracic surgery patients. Anaesthesia 2003;58(5):422-7.
    • [12] Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307- 10.
    • [13] Cote CJ, Daniels AL, Connolly M, Szyfelbein SK, Wickens CD. Tongue oximetry in children with extensive thermal injury: comparison with peripheral oximetry. Can J Anaesth 1992;39(May (5 Pt 1)):454-7.
    • [14] Hampson NB. Pulse oximetry in severe carbon monoxide poisoning. Chest 1998;114(October (4)):1036-41.