LOGIN TO YOUR ACCOUNT

Username
Password
Remember Me
Or use your Academic/Social account:

CREATE AN ACCOUNT

Or use your Academic/Social account:

Congratulations!

You have just completed your registration at OpenAire.

Before you can login to the site, you will need to activate your account. An e-mail will be sent to you with the proper instructions.

Important!

Please note that this site is currently undergoing Beta testing.
Any new content you create is not guaranteed to be present to the final version of the site upon release.

Thank you for your patience,
OpenAire Dev Team.

Close This Message

CREATE AN ACCOUNT

Name:
Username:
Password:
Verify Password:
E-mail:
Verify E-mail:
*All Fields Are Required.
Please Verify You Are Human:
fbtwitterlinkedinvimeoflicker grey 14rssslideshare1
Bryant, M; Farrar, R; Freeman, R; Brummitt, K; Neville, A (2016)
Publisher: Elsevier
Languages: English
Types: Article
Subjects:
The use of cemented femoral stems is common practice worldwide with strong clinical data supporting their use. Over the years, different surface processing techniques have been employed to enhance the performance of the stem-cement interface. As a result different clinical outcomes and visual presentation at revision has been observed. Whilst research has focussed on increasing adhesion and better load bearing capacity, the effects of surface processing on the degradation of cemented femoral stems has not been investigated. The aims of this study was to investigate the effects of surface processing on the subsurface microstructure, surface chemistry and tribocorrosion degradation mechanisms of cemented tapered femoral stems subjected to polishing and blasting (Vaquasheen) processes. Cemented femoral stems were orientated and loaded according to ISO 7206-4 for 500,000 cycles in 0.9% NaCl at 37 °C. A three-electrode electrochemical cell was integrated into the mechanical test to facilitate in-situ corrosion measurements. The severity and mechanism of damaged were assessed scanning and transmission electron microscopy, X-ray photoelectron spectrometry, solution mass spectrometry and white light interferometry. Surface processing influenced the level of tribocorrosion at the interface with polished surfaces demonstrating higher levels of tribocorrosion and ion release when compared to the blasted surfaces. Surface analysis consistently demonstrated the presence of a SiO2 layer on the vaquasheened stems thought to originate from the glass bead blast matrix. This resulted in lower levels of corrosion both under static and tribocorrosion assessment. In conclusion, blasted surfaces resulted in lower wear induced corrosion when compared to the polished surfaces. However the total metallic ion levels did not follow the same trend. This is thought to be due to the formation of metallic debris and dissolution of debris due to abrasion of the femoral stems.
  • The results below are discovered through our pilot algorithms. Let us know how we are doing!

    • 1. Donell, S.T., Darrah, C., Nolan, J.F., Wimhurst, J., Toms, A., Barker, T.H.W., Case, C.P., Tucker, J.K.: Early failure of the Ultima metal-on-metal total hip replacement in the presence of normal plain radiographs. Journal of Bone & Joint Surgery, British Volume 92-B(11), 1501-1508 (2010). doi:10.1302/0301-620x.92b11.24504
    • 2. Hart, A.J., Quinn, P.D., Lali, F., Sampson, B., Skinner, J.A., Powell, J.J., Nolan, J., Tucker, K., Donell, S., Flanagan, A., Mosselmans, J.F.W.: Cobalt from metal-on-metal hip replacements may be the clinically relevant active agent responsible for periprosthetic tissue reactions. Acta Biomaterialia 8(10), 3865-3873 (2013).
    • 3. Bolland, B.J.R.F., Culliford, D.J., Langton, D.J., Millington, J.P.S., Arden, N.K., Latham, J.M.: High failure rates with a large-diameter hybrid metal-on-metal total hip replacement: clinical, radiological and retrieval analysis. Journal of Bone & Joint Surgery, British Volume 93-B(5), 608-615 (2011). doi:10.1302/0301-620x.93b5.26309
    • 4. Webb, J., Spencer, R.: The role of polymethylmethacrylate bone cement in modern orthopaedic surgery. The Journal of Bone and Joint Surgery 89(B) (2007).
    • 5. Willert, H., Broback, L., Buchhorn, G., Jemsen, P., Koster, G., Lang, I., Ochsner, P., Schenk, R.: Crevice corrosion of cemented titanium alloy stems in total hip replacements. Clin Orthop Relat Res 333, 333-351 (1996).
    • 6. Scheerlinck, T., Casteleyn, P.-P.: The design features of cemented femoral hip implants. Journal of Bone & Joint Surgery, British Volume 88-B(11), 1409-1418 (2006). doi:10.1302/0301- 620x.88b11.17836
  • No related research data.
  • No similar publications.

Share - Bookmark

Cite this article