Widger, Phillip; Haddad, Abderrahmane; Griffiths, Huw
Publisher: IEEE
Languages: English
Types: Article
Subjects: TK

Classified by OpenAIRE into

arxiv: Astrophysics::Galaxy Astrophysics
In this paper, sulphur hexafluoride (SF6) insulated vacuum interrupter circuit breakers have been used to explore replacing SF6 gas with a trifluoroiodomethane and carbon dioxide (CF3I-CO2) gas mixture. The search for an alternative insulation gas is driven by the well known extreme global warming potential of SF6. For this purpose, the circuit breaker gas compartment of a piece of gas insulated switchgear (GIS) was filled with a CF3I gas mixture and then tested using lightning impulses up to the rated withstand strength. The tested ring main unit was initially designed to be insulated with SF6 gas. The unit is a three-phase switchgear containing two switches per phase; a selector interlock and a vacuum bottle circuit breaker per phase. The test programme performed in this investigation demonstrated the breakdown performance and insulation strength of the new gas mixture as well as the vacuum circuit breakers behavior when insulated with a new insulation medium. Data on the dielectric properties of the proposed gas mixture is presented, and the performance of the tested vacuum circuit breaker is discussed. Promising results are obtained which indicate the suitability of this more-environmentally friendly gas for high voltage insulation purposes.
  • The results below are discovered through our pilot algorithms. Let us know how we are doing!

    • H. M. Ryan, “Circuit breakers and Interruption,” in Advances in High Voltage Engineering, vol. 40, A. Haddad and D. Warne, Eds., London, IEE Power & Energy Series 40, The Institute of Electrical Engineers, pp. 415-476, 2004.
    • Intergovernmental Panel on Climate Change (IPCC), Working Group I Contribution to Fourth Assessment Report of the IPCC - Intergovernmental Panel on Climate Change, Geneva, Switzerland: Addendum-Errata of Climate Change 2007 - The Physical Science Basis IPCC WG1 AR4 Report, 2008.
    • H. Katagiri, H. Kasuya and S. Yanabu, “Measurement of Iodine Density Generated from CF3I-CO2 Mixture after Current Interruption,” Japan-Korea Joint Symposium on Electrical Discharge and High Voltage Engineering, Shibaura Institute of Technology, Tokyo, 2007.
    • H. Katagiri, H. Kasuya, H. Mizoguchi and S. Yanabu, “Investigation of the Performance of CF3I Gas as a Possible Substitute for SF6,”, IEEE Trans. Dielectr. Electr. Insul., Vol. 15, No. 5, pp. 1424 - 1429, 2008.
    • T. Takeda, S. Matsuoka, A. Kumada and K. Hidaka, “Sparkover and Surface Flashover Charactersitics of CF3I Gas under Application of Nanosecond Square Pulse Voltage,” 16th Int'l. Sympos. High Voltage Eng. (ISH), Paper C-55, pp. 1-6, 2009.
    • M.S. Kamarudin, M. Albano, P. Coventry, N. Harid and A. Haddad, “A survey on the potential of CF3I gas as an alternative for SF6 in high voltage applications,”, 45th Int'l. Universities' Power Engineering Conf.
    • (UPEC), Cardiff University, Wales, UK, 2010.
    • Griffiths and A. Haddad, “CF3I Gas and Its Mixtures: Potential for Electrical Insulation,”, 45th Int'l. CIGRE Session' CIGRE, Paris, France, 2014.
    • B. S. I. (BSI), “British Standard BS62271-1: High-voltage switchgear and controlgear - Part 1: Common specifications,” 2008. [Online].
    • Available: www.bsigroup.com/standards. [Accessed 01 04 2014].
    • P. Widger, Investigation into CF3I-CO2 Gas Mixtures for Insulation of Gas-insulated Distribution Equipment”. PhD Thesis, Cardiff University, Wales, UK, 2014.
    • [10] Lucy Switchgear, “SABRE VRN6a SF6 RMU Automated distribution solutions - towards smarter electrical networks,” Selangnor, Malysia: Lucy Switchgear, LS00001 SABRE VRN6a (Asia) 06 2013 9776, 2013. [Online]. Available: www.lucyswitchgear.com [Accessed 04 07 2013]
    • [11] Lucy Switchgear, SCRMU Instruction & Operation Manual Medium Voltage 12 -24 kV, Oxford: Lucy Switchgear, 1999.
    • [12] Lucy & Co. Ltd. Oxford., Lucy Swithgear SCRMU(M) Faceplate, Oxford: Lucy Switchgear, 2000.
    • [13] R. H. Petrucci, W. S. Harwood and F. G. Herring, General Chemistry Principles and Modern Applications (8th Edition), Eighth Edition, Upper Saddle River, New Jersey, New Jersey: Prentice-Hall Inc., ISBN 0-13-014329-4, 2002.
    • [14] British Standard Institution (BSI), “BS EN 60060-1: High-voltage test techniques Part 1: General definitions and test requirements,” 2010. [Online]. Available: www.bsigroup.com/standards. [Accessed 01 04 2011].
  • No related research data.
  • Discovered through pilot similarity algorithms. Send us your feedback.

Share - Bookmark

Cite this article