LOGIN TO YOUR ACCOUNT

Username
Password
Remember Me
Or use your Academic/Social account:

CREATE AN ACCOUNT

Or use your Academic/Social account:

Congratulations!

You have just completed your registration at OpenAire.

Before you can login to the site, you will need to activate your account. An e-mail will be sent to you with the proper instructions.

Important!

Please note that this site is currently undergoing Beta testing.
Any new content you create is not guaranteed to be present to the final version of the site upon release.

Thank you for your patience,
OpenAire Dev Team.

Close This Message

CREATE AN ACCOUNT

Name:
Username:
Password:
Verify Password:
E-mail:
Verify E-mail:
*All Fields Are Required.
Please Verify You Are Human:
fbtwitterlinkedinvimeoflicker grey 14rssslideshare1
Silva, Felipe Martins Marques da; Centeno, Jorge Antonio Silva (2016)
Publisher: Universidade Federal do Paraná
Languages: Portuguese
Types: Unknown
Subjects: Iluminação ambiente, Câmera de distância, Erros, Background illumination, Range camera, Errors
As câmeras de distância são capazes de medir a distância entre o sensor e a superfície dos objetos para cada pixel da imagem, em um único instante, produzindo uma imagem de distâncias. Além das distâncias, também obtém a intensidade e a amplitude para cada pixel, formando as imagens de intensidade e amplitude, respectivamente. Como toda a medida, aquelas obtidas pelas câmeras de distância possuem erros, e um dos fatores que geram erros nas medidas é a iluminação ambiente. Neste estudo foi analisada a influência que a iluminação ambiente exerce sobre os valores calculados de distância, amplitude e intensidade. Para isso, realizou-se experimentos em uma sala escura, onde foram obtidas imagens de distância, intensidade e amplitude de uma parede branca, em que incidia diversos níveis de iluminação gerada por duas lâmpadas cujos feixes convergiam ao centro da parede. Verificou-se que: a iluminação fornecida nos experimentos aumentou os valores de distância; a relação entre os erros de distância e a variação da amplitude é diretamente proporcional e linear; e que a relação entre os erros de distância e a variação da intensidade também se mostrou linear para valores de intensidade menores que 26600, para a frequência de modulação de 21 MHz. As correlações lineares atingiram valores acima de 0,9. A imagem de intensidade se mostrou mais sensível à incidência de iluminação ambiente do que a imagem de amplitude. Range cameras are able to measure the distance between the sensor and the surface of objects for each image pixel, in a just single instant, producing an image of distance. It also measure the intensity and amplitude for each pixel, in order to produce images of intensity and amplitude, respectively. Like any measure, those obtained by the distance of cameras have errors, and one of the factors that produces errors in the measurements is the external lighting at the environment. In this study it was analyzed the influence of the external lighting on the calculated values of distance, amplitude and intensity. In a dark room it was made up some experiments, where it was obtained images of distance images, intensity and amplitude of a white wall, where various lighting levels generated by two lamps whose beams converged on the center of the wall. Some conclusions are: the external illumination increased distance values; the ratio of the distance error and the amplitude variation is directly proportional and linear; and the relationship between the distance error and the variation of intensity it was also linear for values lower intensities than 26600, at 21 MHz of modulation frequency. It was achieved linear correlation above 0.9. The image of intensity is more sensitive to the effect of external lighting than the amplitude image

Share - Bookmark

Cite this article